WD30EFRX ошибки smart
привет форумчане прошу помощи
Есть Xenserver к которому были недавно подключены 2 диска WD30EFRX диски новые и все смарт показатели были проверены перед началом работы. Ошибок не было. Работа под нагрузкой тоже была без ошибок. Далее диски были проброшены ка блочное устройство в виртуалку где их разбили на части и создали lvm (lvcreate -i3 -I512K -n lv02 -l100%free vg02). В процессе копирования информации оба диска получили ошибки по смарт.
=== START OF INFORMATION SECTION ===
Model Family: Western Digital Red (AF)
Device Model: WDC WD30EFRX-68EUZN0
Serial Number: WD-WCC4N6ZTPU8V
LU WWN Device Id: 5 0014ee 262d24f3a
Firmware Version: 82.00A82
User Capacity: 3,000,592,982,016 bytes [3.00 TB]
Sector Sizes: 512 bytes logical, 4096 bytes physical
Rotation Rate: 5400 rpm
Device is: In smartctl database [for details use: -P show]
ATA Version is: ACS-2 (minor revision not indicated)
SATA Version is: SATA 3.0, 6.0 Gb/s (current: 3.0 Gb/s)
Local Time is: Tue Jul 3 11:55:51 2018 EEST
SMART support is: Available - device has SMART capability.
SMART support is: Enabled === START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (38760) seconds.
Offline data collection
capabilities: (0x7b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 2) minutes.
Extended self-test routine
recommended polling time: ( 389) minutes.
Conveyance self-test routine
recommended polling time: ( 5) minutes.
SCT capabilities: (0x703d) SCT Status supported.
SCT Error Recovery Control supported.
SCT Feature Control supported.
SCT Data Table supported. SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0
3 Spin_Up_Time 0x0027 180 179 021 Pre-fail Always - 6000
4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 9
5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0
7 Seek_Error_Rate 0x002e 100 253 000 Old_age Always - 0
9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 41
10 Spin_Retry_Count 0x0032 100 253 000 Old_age Always - 0
11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 9
192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 2
193 Load_Cycle_Count 0x0032 200 200 000 Old_age Always - 36
194 Temperature_Celsius 0x0022 117 110 000 Old_age Always - 33
196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0
197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0
198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0
199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0
200 Multi_Zone_Error_Rate 0x0008 100 253 000 Old_age Offline - 0 SMART Error Log Version: 1
Warning: ATA error count 36172 inconsistent with error log pointer 4 ATA Error Count: 36172 (device log contains only the most recent five errors)
CR = Command Register [HEX]
FR = Features Register [HEX]
SC = Sector Count Register [HEX]
SN = Sector Number Register [HEX]
CL = Cylinder Low Register [HEX]
CH = Cylinder High Register [HEX]
DH = Device/Head Register [HEX]
DC = Device Command Register [HEX]
ER = Error register [HEX]
ST = Status register [HEX]
Powered_Up_Time is measured from power on, and printed as
DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes,
SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 36172 occurred at disk power-on lifetime: 36 hours (1 days + 12 hours)
When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 00 00 e0 00 09:48:28.927 READ DMA Error 36171 occurred at disk power-on lifetime: 36 hours (1 days + 12 hours)
When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 00 00 e0 00 09:47:39.801 READ DMA Error 36170 occurred at disk power-on lifetime: 36 hours (1 days + 12 hours)
When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 00 00 e0 00 09:46:49.532 READ DMA Error 36169 occurred at disk power-on lifetime: 36 hours (1 days + 12 hours)
When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 08 00 e0 Error: UNC 8 sectors at LBA = 0x00000800 = 2048 Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 08 00 e0 00 09:43:02.611 READ DMA Error 36168 occurred at disk power-on lifetime: 35 hours (1 days + 11 hours)
When the command that caused the error occurred, the device was active or idle. After command completion occurred, registers were:
ER ST SC SN CL CH DH
-- -- -- -- -- -- --
40 51 08 00 00 00 e0 Error: UNC 8 sectors at LBA = 0x00000000 = 0 Commands leading to the command that caused the error were:
CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name
-- -- -- -- -- -- -- -- ---------------- --------------------
c8 00 08 00 00 00 e0 00 09:16:48.118 READ DMA SMART Self-test log structure revision number 1
Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error
# 1 Short offline Completed without error 00% 41 -
# 2 Extended offline Aborted by host 90% 41 -
# 3 Short offline Completed without error 00% 40 - SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
[root@XEN ~]# smartctl -a /dev/sdd
smartctl 6.2 2013-07-26 r3841 [x86_64-linux-4.4.0+10] (local build)
Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org
Диски были выведены из виртуалки вся информация на них была снесена. Пытаюсь понять где я накосячил с разбивкой диска и можно ли убрать эти ошибки?